Guide

What is a pull tester?

In short

A pull tester, also called an anchor tester, anchor pull tester, fixings tester, pull-out tester or proof load tester, is a portable tool that pulls on an installed anchor, eyebolt or scaffold tie anchor and shows the load applied. Bench testers for crimped wire terminals or garment snaps share the name but are different machines.

This guide explains how site tests are planned and carried out under BS 8539:2012+A1:2021. It does not replace the standard, the anchor manufacturer's data, or the instructions of the specifier or engineer responsible for the job, who decides the test plan, the loads and the factors. A test records what happened on the day; it does not approve a fixing for use.

Key figures

Also calledAnchor tester, anchor pull tester, fixings tester, pull-out tester, proof load tester
Staht t25 and t6025 kN and 60 kN; ±1.5% of full scale, as stated by Staht (±0.375 kN and ±0.9 kN)

What does a pull tester or anchor tester do?

It applies a measured pull to a fixing where it is installed. A test records what happened on the day; it doesn't approve a fixing. The specifier or responsible engineer decides the test plan. See when to site test anchors.

What is the difference between a pull-out test and a proof test?

A proof test loads an installed anchor to a set proof load to check it was installed correctly. Under BS 8539 that is the unfactored (characteristic) load on the anchor, N_Ek, times 1.5 where at least 2.5% of anchors are tested or 1.25 where at least 5% are, and no more than 1.5 times the maker's recommended load; the anchor passes if it holds without moving or damage, and stays in use. Under NASC TG4:25 it is 1.25 times the scaffold tie duty. See BS 8539 proof testing and scaffold tie proof testing.

"Pull-out test" is used loosely on site for any pull test. In the narrower sense, it is a test that loads an anchor to find what it can carry, often until it fails: preliminary tests and tests to failure, on anchors installed for the test and not used afterwards. "Pull-out" is also one way an anchor fails: see failure modes. Our test load calculator works out a BS 8539 preliminary test load.

How is it different from a wire or garment pull tester?

The same name is used for bench machines that pull a crimped terminal off its wire, or pull on snaps and buttons fixed to clothing and toys. They work in a factory or laboratory, on far smaller forces. A construction pull tester is portable, reads in kilonewtons (kN) and goes to the fixing on site.

How does an anchor pull tester work?

A portable pull tester has four parts:

  1. The load cell or hydraulic ram. Usually, turning a nut or handle on a threaded rod pulls on the fixing, and the pull passes through a hydraulic load cell whose oil pressure is shown as load. On the Staht t25 and t60 the gauge is digital and built in; the t60 reaches 60 kN at under 25 Nm of torque.
  2. The bridge. Its legs bear on the surface around the fixing and take the reaction. How far apart they are matters for some tests: see bridge leg spacing.
  3. The adaptor. It connects the tester to the fixing: threaded washers or couplers for studs, slotted washers for bolt heads, a clevis for eyebolts and rings.
  4. The readout. A dial or digital screen shows the load, and should hold the peak after the reading falls back. The t25 and t60 show live and peak load together and send each result to an app.

What types of pull tester and anchor tester are there?

TypeHow it worksTypical useStaht example
Digital pull testerHydraulic load cell read by a digital gauge in kN, often with Bluetooth and an appAnchors, eyebolts, scaffold tie anchors[t25](/products/t25-digital-pull-tester-kit-with-mini-hd-case) (25 kN), [t60](/products/t60-digital-pull-tester-kit-with-case-and-app-accessories) (60 kN)
Pull tester with a dial gaugeThe same, read on an analogue dial gaugeAs aboveNone
Heavy duty hydraulic kitOften a hand pump, hose and hollow hydraulic ram, with a pressure gauge and a chart for the ramLarge anchors, holding-down bolts and rebar[Heavy duty kits](/c/heavy-duty-testers), 176 kN and 358 kN
In-line testerMeasures the force between two pointsFall protection posts, lifting points, rail systems[In-line kit](/c/in-line-testers), used with a t25 load cell (not included), up to 25 kN
Swage or lifeline testerGrips a cable lifeline and loads its swaged end fitting8 mm cable lifelines, to the line maker's test force[LT swage tester](/c/lt-line-testers), up to 25 kN
Shear rigLoads a fixing sideways through a sliding head, from a frame anchored beside itAnchors in shear, in concrete and masonry[Shear test rig](/c/shear-testers), with a t25 or t60 load cell

Which standards and guidance relate to pull testing?

StandardPublisherWhat it covers
BS 8539:2012+A1:2021 Code of practice for the selection and installation of post-installed anchors in concrete and masonryBSIChoosing and installing anchors in drilled holes in concrete and masonry, including site tests to find allowable loads, and proof tests
NASC TG4:25 Anchorage Systems for ScaffoldingNASCChoosing, installing and testing the anchors that tie scaffolds: preliminary tests where in doubt, proof tests on every job
BS 7883:2019 Personal fall protection equipment. Anchor systems. System design, installation and inspection. Code of practiceBSIDesign, installation, use, maintenance and inspection of anchor systems for personal fall protection
BS EN 795:2012 Personal fall protection equipment. Anchor devicesBSIA product standard: performance requirements and test methods for single-user anchor devices that can be removed from the structure

How do the standards fit together?

NASC TG4:25 covers the anchors that tie scaffolds and lists BS 8539 among its references; for fall arrest loads it points the scaffold designer to SG4, BS EN 795 and BS 7883. BSI lists all three British Standards as current and under review. TG4:25 was issued in March 2025.

How do I choose an anchor tester?

  1. Capacity. Cover the highest load you'll apply, without oversizing: where accuracy is a share of full scale, a bigger tester has a bigger error in kN, which matters most at low loads.
  2. Accuracy, and how it's stated. "±1.5% of full scale" allows the same possible error in kN at every reading: up to ±0.375 kN on a 25 kN tester, which could be 7.5% of a 5 kN reading. "±1.5% of reading" would be ±0.075 kN at 5 kN. For BS 8539 site tests the gauge should read within 10% of the true load; NASC TG4:25 asks for 5%, without saying of what. See gauge accuracy.
  3. Bridge spacing. For preliminary tests and tests to failure, how far the legs stand from the anchor affects the result. The t25 and t60 bridges give 127 mm clear between the feet along the bridge; Staht's modular bridges give 375 mm (25 or 60 kN) and 575 mm (25 kN). See bridge leg spacing.
  4. Adaptors. Check the kit fits your fixings: the t25 takes M6 to M16, the t60 M6 to M20, both with a clevis for eyebolts. See adaptors explained.
  5. Digital records. Staht Connect records each test's peak load, target load, pass or fail and time, with photos and a map pin. See what a test report should record.
  6. Calibration. It should come with a certificate.

For a buyer's checklist by job and load, and to match a Staht kit to the job, see which pull tester to buy, and the kit checklist for the rest of what to take.

How often does a pull tester need calibrating?

At least every 12 months, by a laboratory whose reference equipment is traceable to national standards, and again after a drop or any reading you doubt. NASC TG4:25 asks for a gauge calibrated within the last 12 months. Keep the certificate and put the calibration date in each test report.

Staht t25 and t60 kits come with a 12-month certificate. Staht calibrates and services them, and their annual calibration can also be done by a local calibration laboratory.

Should I hire or buy a pull tester?

Hire suits a one-off job; buy for regular testing. Staht hires t25 kits for at least 7 days, calibrated and with their certificate.

More questions

More on testing anchors and fixings

Sources

  1. BS 8539:2012+A1:2021 Code of practice for the selection and installation of post-installed anchors in concrete and masonry, BSI
  2. NASC TG4:25 Anchorage Systems for Scaffolding, NASC
  3. BS 7883:2019 Personal fall protection equipment. Anchor systems. System design, installation and inspection. Code of practice, BSI
  4. BS EN 795:2012 Personal fall protection equipment. Anchor devices, BSI
  5. Staht t25 kit data sheet, TDS 133, Staht
  6. Staht t60 kit data sheet, TDS 100, Staht

Find the right pull tester

The t25 and t60, with the Staht Connect app.

Your basket

Loading your basket…