Guide

Which pull tester should I buy?

In short

Choose by the job and the highest load you'll apply. Then check the tester's accuracy at your test loads, that it holds the peak, what reporting costs, calibration, what's in the kit and its weight. A 25 kN tester covers every NASC TG4:25 scaffold tie proof load; larger anchors may need 60 kN, and rebar a heavy duty kit.

This guide explains how site tests are planned and carried out under BS 8539:2012+A1:2021. It does not replace the standard, the anchor manufacturer's data, or the instructions of the specifier or engineer responsible for the job, who decides the test plan, the loads and the factors. A test records what happened on the day; it does not approve a fixing for use.

Key figures

Scaffold tie proof loads, NASC TG4:254.4 to 15.3 kN (1.25 × the tie duty)
Staht testers by capacityt25 25 kN; t60 60 kN; heavy duty kits 176 kN and 358 kN
Staht t25 and t60 accuracy±1.5% of full scale: ±0.375 kN and ±0.9 kN
Staht Connect app and reportsFree, with no subscription, for one user or a team
Staht t25 weightLoad cell 1.39 kg, bridge 2.72 kg; 9 kg as a four-leg kit in its mini case
Pull tester hire from Stahtt25 kits, 7 days minimum, £150 a week ex VAT

Which pull tester for which job?

JobWhat sets the test loadWhat to look forStaht kit
Scaffold tie anchors (NASC TG4:25)Proof tests: 1.25 × the tie duty, 4.4 to 15.3 kN. Preliminary tests: 2 × the tie duty, 7.0 to 24.4 kN, or 3 × for nylon anchors unless the maker says otherwise, 10.5 to 36.6 kNA gauge calibrated within the last 12 months to an accuracy of 5% (TG4:25 doesn't say of what). 25 kN covers every proof load; the t25's ±0.375 kN is within 5% of the reading from 7.5 kN, and 8.5% of the 4.4 kN light duty load[t25](/products/t25-digital-pull-tester-kit-with-mini-hd-case), three or four legs; [t60](/products/t60-digital-pull-tester-kit-with-case-and-app-accessories) for nylon preliminary tests above 25 kN (on 9.1 and 12.2 kN ties)
Fall arrest anchors and safety eyeboltsThe anchor maker or the system designer. BS 7883:2019 covers anchor systemsA clevis for eyes and rings, and a bridge that stands clear of the fittingt25 or t60 with the clevis, which has a captive pin
Anchors in concrete and masonry (BS 8539)The specifier. Proof load: the unfactored load × 1.5 (at least 2.5% tested) or × 1.25 (at least 5%), and no more than 1.5 × the maker's recommended load. Preliminary tests are higherAdaptors for the thread; for preliminary tests, feet far enough from the anchort25 (M6 to M16) or t60 (M6 to M20); [375 mm and 575 mm bridges](/c/bridges)
Large anchors and rebarThe specifierA hollow ram, pump and gauge, with a way to turn pressure into load[Heavy duty kits](/c/heavy-duty-testers), 176 kN or 358 kN, 51 mm stroke; rebar adaptors available
Lifeline swagesThe lifeline system's maker gives the test forceA frame that grips the cable[LT swage tester](/c/lt-line-testers): 8 mm cable (7x7 or 1x19), up to 25 kN, with a t25 load cell
Force between two pointsThe system's maker or designerA load cell that fits in line[In-line kit](/c/in-line-testers), up to 25 kN with a t25 load cell (not included): fall protection posts, overhead lifting points, rail systems
Anchors in shearThe specifier. NASC TG4:25 says shear tests are rarely needed for scaffold anchors and, on site, generally impracticalA rig fixed beside the anchor that loads it sideways[Shear test rig](/c/shear-testers), bushes M6 to M20: up to 25 kN with a t25 load cell, or 60 kN with a t60

What load range do I need?

Work out the highest test load first: for BS 8539 preliminary tests, the test load calculator does it. Then pick the smallest range that covers it:

  • Up to 25 kN: a 25 kN tester such as the t25. The LT swage tester and the in-line kit use the t25 load cell, so they also stop at 25 kN, as does the shear test rig with a t25 load cell.
  • 25 to 60 kN: a 60 kN tester such as the t60.
  • Above 60 kN: a hydraulic kit with a hollow ram, such as Staht's 176 kN and 358 kN heavy duty kits.

Don't oversize. Where accuracy is a share of full scale, a bigger tester has a bigger possible error in kN at every reading, which matters most at low loads. Within 10% of the reading, the t25 is good from 3.75 kN and the t60 from 9 kN; within 5%, from 7.5 kN and 18 kN.

What should I check before buying?

  1. Range against the test load, as above.
  2. Read-out and peak hold. Anchors relax under load, and a failing anchor lets the load fall away, so the gauge must keep showing the highest load. The t25 and t60 show live and peak load together on screen, and Hydrajaws' digital gauges have peak hold.
  3. Accuracy, and how it's stated. Check whether it's a share of full scale or of the reading. Staht states ±1.5% of full scale for the t25 and t60 load cells; Hydrajaws states "+/-1.5% fsd" for the digital gauges of the M2000 and M2050, and no figure for the M35+. For BS 8539 site tests a gauge should read within 10% of the load, and NASC TG4:25 asks for 5%, without saying of what. See gauge accuracy.
  4. Reporting, and what it costs. The Staht Connect app and its reports at app.staht.com are free, with no subscription, including team use: several users and team reporting. Hydrajaws says its Verify PRO app, used with its digital gauge, is "FREE to use with no subscription required"; Verify TEAMS, which lets an administrator manage clients, sites and tasks centrally and assign them to field testers, is paid: "Annual subscription fee applies. Up to 3 users £300", ex VAT (Hydrajaws' Verify page, read 8 November 2026). See what a test report should record.
  5. Calibration. A tester should come with a certificate and be recalibrated at least every 12 months. Staht t25 and t60 kits come with a 12-month certificate; Staht calibrates them, or a local calibration laboratory can do it digitally. With a detachable Hydrajaws gauge, only the gauge is sent.
  6. What's in the kit. Check the adaptors fit your fixings: the t25 kits have threaded and slotted washers for M6 to M16 and a clevis, and the t60 threaded washers to M20. Threaded adaptors from M22 to M30 fit Staht's M16 drop rod. See adaptors explained.
  7. Weight, in the table below.
  8. Leg spacing. For preliminary tests and tests to failure, the feet must stand far enough from the anchor. The t25 and t60 bridges give 127 mm clear between the feet along the bridge and 59 mm across; Staht's modular bridges give 375 mm or 575 mm along the bridge. See bridge leg spacing.
  9. Stroke. The tester's travel should be longer than the movement you expect. Hydrajaws gives 50 mm for the M2000 and M2050. Staht doesn't publish a stroke for the t25 or t60: ask us.

How much do pull testers weigh?

TesterRangeWeight, as the maker publishes it
Staht t25, four legs, mini case kit0 to 25 kNLoad cell 1.39 kg, bridge 2.72 kg; kit 9 kg
Staht t60, case kit0 to 60 kNKit 10.1 kg; packaged 10.8 kg
Hydrajaws M2000 PRO0 to 25 kN"Tester only 2.2kg"; case 10 kg (leaflet), packaged 8 kg (manual)
Hydrajaws M35+35 kN, or 65 kN with the medium or large bridge"Tester only: 3.7kg"; standard kit with rucksack 8.7 kg
Hydrajaws M2050 PRO0 to 50 kN"Tester only: 2.5kg"; packaged 14 kg (manual), case 16 kg (leaflet)

Hydrajaws' published "tester only" weights, 2.2 to 3.7 kg, are lower than the t25's load cell and bridge together (1.39 kg and 2.72 kg). They aren't measured the same way: Hydrajaws doesn't say what its "tester only" figure includes. Hydrajaws' figures are from its own pages, leaflets and manuals, read on 8 November 2026 (see Sources); check each maker's current information. Compared in detail: Staht and Hydrajaws testers.

Should I hire instead?

Hire suits a one-off job; buy for regular testing. Staht hires t25 kits, three- or four-leg, for at least 7 days, calibrated and with their certificate: £150 a week ex VAT, then £50 a day ex VAT, with a £500 deposit refunded once the kit is back and checked, less any charges the hire terms allow.

Where do Staht's testers fit?

Staht wrote this guide. It makes the t25 and t60 and supplies all the kits above. The t25 won Product of the Year at the Scaffolding Excellence Awards 2025, run by NASC. To match a Staht kit and adaptors to your job, ask us; for the basics, see what a pull tester is.

More questions

Hydrajaws products are made by Hydrajaws Limited, a separate company from Staht Limited.

Sources (other makers' figures read on 8 November 2026)

  1. NASC TG4:25 Anchorage Systems for Scaffolding, NASC
  2. BS 8539:2012+A1:2021 Code of practice for the selection and installation of post-installed anchors in concrete and masonry, BSI
  3. BS 7883:2019 Personal fall protection equipment. Anchor systems. System design, installation and inspection. Code of practice, BSI
  4. Staht t25 kit data sheet, TDS 133, Staht
  5. Staht t60 kit data sheet, TDS 100, Staht
  6. Staht t25 load cell data sheet, TDS 134, Staht
  7. Staht t25 bridge data sheet, TDS 135, Staht
  8. Staht wins Product of the Year at Scaffolding Excellence Awards, Staht
  9. Scaffolding and access the winner on a star-studded night of celebration, NASC
  10. Hydrajaws M2000 PRO Tester Kit, product page, Hydrajaws
  11. Hydrajaws M2000 PRO leaflet 132-177 v1.1, Hydrajaws
  12. Hydrajaws M2000 operating instructions 132-113 v1.6, Hydrajaws
  13. Hydrajaws M2050 PRO leaflet 132-183 v1.1, Hydrajaws
  14. Hydrajaws M2050 manual 132-016 v4.1, Hydrajaws
  15. Hydrajaws M35+ leaflet 132-234 v1.2, Hydrajaws
  16. Hydrajaws M35+ product page, Hydrajaws
  17. Hydrajaws M35+ user manual 132-220 v1.1, Hydrajaws
  18. Hydrajaws Verify digital reporting system, Hydrajaws
  19. Hydrajaws gauge calibration, Hydrajaws

Find the right pull tester

The t25 and t60, with the free Staht Connect app.

Your basket