What Is a Pull Tester? Anchor and Fixings Testers Explained
A pull tester, or anchor tester, loads a fixing on site and shows the load: how it works, the types, BS 8539 and TG4:25, accuracy and calibration.
A pull tester, or anchor tester, loads a fixing on site and shows the load: how it works, the types, BS 8539 and TG4:25, accuracy and calibration.
How to choose a pull tester or anchor tester: match it to the job and the test load, then check accuracy, peak hold, reports, calibration and weight.
Staht t25 and t60 beside Hydrajaws' M2000 PRO, M2050 PRO and M35+ and Leach's Big Ben (BIGBEN) kits: capacity, display, accuracy, app, team use and standards.
BS 8539 site tests have two jobs: finding an allowable load where no data exists, and proof testing at least 2.5% of installed anchors. When each applies.
BS 8539 proof tests load at least 2.5% of anchors (min. 3) to 1.5 × the characteristic action, or at least 5% to 1.25 ×. Samples, pass criteria, failures.
Preliminary tests load 5 anchors to Ntest = NEk × νtest ÷ (αdist × Ω). How to find each factor, with four worked examples and what to do if one fails.
Bridge supports under 3 × hef apart can raise a test result, so BS 8539 applies αdist = 0.4 + adist ÷ (5 hef). Spacing rules and which bridge to use.
How to connect a pull tester to studs, bolt heads, eyes and rebar: couplers need thread engagement of at least 1.5 × the bolt diameter. Adaptors explained.
A pull tester gauge should read within 10% of the true load and be calibrated every 12 months. How full-scale accuracy limits low readings, with examples.
First movement is the load at which an anchor starts to move, usually at 0.1 mm. How to record it, tell relaxation from failure, and read failure modes.
On brickwork, set bridge feet on the neighbouring bricks; in blocks, keep them at least 1.5 × h_ef from the anchor. How to place, load and assess tests.
An anchor pull test report states facts: who, where, which anchor, the load asked for and the load held. What BS 8539 says a test report should record.
Anchors are shear tested on site mainly to find an allowable resistance where no shear data exists. Proof tests are not needed in shear. How the rig works.
What to pack for an anchor test day: a tester calibrated in the last 12 months, bridge, adaptors, torque wrench, hole cleaning kit, PPE and paperwork.
Work out a BS 8539 preliminary test load, Ntest = NEk × νtest ÷ (αdist × Ω), or a proof load of 1.25 or 1.5 × N_Ek. Method, inputs and two examples.
NASC TG4:25 in practice: find the tie duty, check the wall, choose the anchor, preliminary test 5 where data is lacking, proof test 5% of anchors per job.
Under NASC TG4:25, scaffold tie anchors are proof tested at 1.25 × the tie duty and preliminary tested at 2 × (3 × for nylon). Worked loads, tester sizes.
TG4:25 preliminary tests load 5 anchors per base material to 2 × the tie duty. If any fails, an engineer decides; more anchors use average ÷ 3, lowest ÷ 2.
NASC TG4:25: proof test at least 5% of scaffold tie anchors (1 in 20, at least 3 per area) at 1.25 × the tie duty. One failure doubles the rate to 1 in 10.
Drop-in sockets and ring bolts suit concrete and hard stone only; screws, nylon plugs and resin anchors suit brickwork. Choosing a scaffold tie anchor.
NASC TG4:25: check scaffold tie anchors at every statutory inspection, and proof test again if needed after severe weather. What to look for, and retests.
What each term and symbol in the guides means, from NEk and hef to proof load and first movement.
Download brochures and technical data sheets for Staht pull testing equipment.
Hands-on training for Staht digital pull testing systems. Learn from our engineers at our Stourbridge facility or on-site at your location.
Frequently asked questions about Staht products, calibration, ordering, and support.
Calibration and servicing for Staht pull testers and other brands, with UKAS-traceable certificates.
Get help with Staht products — FAQs, calibration services, returns, and technical support.
Seven kinds of test, from scaffold ties to rebar: which kit, which adaptor and how it's recorded.
Test scaffold tie anchors with the award-winning Staht t25 digital pull tester, to 25 kN, and record every tie test in the free Staht Connect app.
Test installed safety eyebolts and fall arrest anchor points with a Staht t25 or t60 and clevis, or measure between anchor posts with the in-line kit.
Test swage terminations on 8 mm (7x7 or 1x19) safety lifelines up to 25 kN with the Staht LT and a t25 load cell, and record each test in the app.
Measure force between two anchorage points up to 25 kN with the Staht in-line kit and your t25 load cell: anchor posts, lifting points and rail systems.
Proof load test Reid Lifting davit installations, flush and top mount bases, with a Staht t25 or t60 and the davit testing adaptor kit.
Pull test rebar and large anchors with the Staht heavy duty kits: 176 kN or 358 kN hollow cylinders, rebar adaptors R6 to R32 and a Bluetooth gauge.
Test post-installed anchors in concrete and masonry in tension with a t25 or t60, in shear with the Staht shear test rig, and big ones with heavy duty kits.
What scaffolders must test on tie anchors under NASC TG4:25: proof tests on 5% (1 in 20) every job at 1.25 x tie duty, preliminary tests, records and tags.
What the Work at Height Regulations 2005 and BS 7883:2019 ask of anchor points, eyebolts and lifelines: inspection before use, at intervals, records.
A building owner's duties for roof anchors, eyebolts and lifelines (Work at Height Regulations) and cradles (LOLER, at least every 6 months), and the records.
Rope access anchors under the Work at Height Regulations and IRATA's code: two anchored lines, 15 kN static strength, 6-monthly inspection, competence.
Anchor testing on construction sites under BS 8539: when tests are needed, proof tests on 2.5% (at least 3), who sets the load, temporary works and records.
Roof anchor and eyebolt testing for installers and inspectors: inspection before first use and at intervals, proof loads from the designer, records and kit.
Testing a horizontal lifeline's parts: end anchors with a t25 or t60, 8 mm swages with the LT to 25 kN, and force between posts with the in-line kit.
Window cleaning eyebolts are fall arrest anchors HSE says must be inspected and tested periodically by a competent person: records, LOLER, testing, hire.
Davits that suspend a cradle or BMU are lifting equipment: LOLER thorough examination at least every 6 months, the reports to keep, and socket proof tests.
IRATA's figures for rope access anchors: 15 kN static strength, three 15 kN trial tests for 3 minutes, a 6 kN proof load at detailed inspection, and the kit.
How contractors and temporary works coordinators build BS 8539 anchor tests into a job: who sets them, discrete areas, requests, failures, records.
Rebar and holding-down bolt pull-out tests on site: hollow cylinder kits to 176 or 358 kN, test loads from the designer, pressure to load, safety and records.
Free fillable anchor pull test report from Staht: the job, anchor and test load, installation, each anchor's result, equipment, calibration and sign-off.
Free fillable scaffold tie anchor test record with cut-out tags: site, anchor, base material, minimum test load, load reached, pass or fail, for NASC TG4:25.
Free fillable proof load test record for anchors, eyebolts and anchor points: what was tested, the proof load and who set it, load held, result and tester.
A free 20 to 25 minute talk to NASC TG4:25: editable PowerPoint, PDF and sign-off sheet.