Guide

What is a test gauge?

In short

A test gauge is a pressure gauge accurate enough to test equipment or check other gauges, rather than to watch a process. ASME B40.100, the US standard, defines accuracy grades; gauge makers such as Ashcroft put test gauges at grade 3A (±0.25% of span) or 4A (±0.1% of span), where the lower grades A and B allow ±1% to ±3%. A test gauge is calibrated more carefully, handled more gently and kept for testing, not left on a machine.

Test gauges and process gauges

Test gaugeProcess gauge
JobTesting equipment, checking or calibrating other gaugesShowing a machine or line's pressure
Typical accuracy (ASME B40.100 grades)3A ±0.25% or 4A ±0.1% of spanLower grades, such as A (±1% mid-scale, ±2% at the ends) or B (±2% to ±3%)
Where it livesIn its case, brought to the jobFitted to the machine or pipe
CalibrationCalibrated regularly against a better reference, with the certificate kept and quoted in test reportsChecked against a test gauge

Why a test gauge must be more accurate

To check a gauge, the reference has to be clearly better than the gauge under test, or you can't tell the reference's error from the gauge's. Calibration practice traditionally asks for the reference's uncertainty to be at least four times smaller than the instrument's (a 4:1 ratio). So a ±1% process gauge is checked with a gauge of ±0.25% or better. See how to calibrate a pressure gauge.

Master gauges and reference gauges

A master gauge or reference gauge is a test gauge kept to check other gauges, often in a workshop or calibration room, and used less so it drifts less. It must itself be calibrated against a better reference, back to national standards: a traceable calibration. See how often to calibrate a pressure gauge.

Test gauges for site tests

On site, the gauge that reads a test is the evidence: load and proof tests are reported from its reading. For anchor tests to BS 8539 and NASC TG4:25, the test gauge must have been calibrated within the last 12 months, and its error at the test load matters more than its full-scale figure. See pressure gauge accuracy and pull tester gauge accuracy.

Looking after a test gauge

  • Keep it in its case and away from shocks: a drop can shift its calibration.
  • Use it within its range: never above its maximum.
  • Check its zero before each use.
  • Recalibrate at the interval you set, and after any drop, overload or doubtful reading.

The Staht G1 Pro

Whichever gauge you use, check its accuracy at the pressure you test at against what your test standard asks for.

The G1 Pro is calibrated for one year from purchase, with a UKAS traceable certificate, and Staht recommends calibration every year. The Staht G1 Pro is a calibrated digital Bluetooth pressure gauge for hydraulic pumps and cylinders, reading up to 1000 bar (14,504 psi), accurate to 0.25% of full scale (±2.5 bar, ±36 psi) and UKAS traceable. Its colour screen shows the pressure in bar, live and peak, and the free Staht Connect app shows the force in kN or lbf from the cylinder's piston area. £585.00 ex VAT (£702.00 inc VAT). See all our digital pressure gauges.

Questions

Sources

  1. What are ASME accuracy grades for mechanical pressure gauges?, Ashcroft
  2. Pressure comparators and digital reference pressure gauges vs deadweight testers, Fluke
  3. Pull tester gauge accuracy, Staht
  4. Staht G1 Pro gauge user manual, Revision 1, 04/02/2026, Staht
  5. Staht Heavy Duty Test Kit brochure (the G1 Pro's range and accuracy), Staht
  6. Pressure gauge calibration, Staht

A calibrated gauge to 1000 bar

Accurate to 0.25% of full scale, with peak hold and a free app that records each test. £585.00 ex VAT.

Your basket

Loading your basket…