Hydraulic pressure gauges

In short
A hydraulic pressure gauge reads the oil pressure in a hydraulic pump, hose or cylinder, usually in bar and psi. Many high-pressure tools, cylinders and jacks are rated to 700 bar (10,000 psi), so their gauges need a range above that, accuracy that holds at the pressures you test at, a way to keep the peak, and a thread that fits the pump or coupler. To get the force from a cylinder, multiply the pressure by its piston area: kN = bar × cm² ÷ 100.
Pump, gauge, hose and cylinder
- Pump: a hand or powered pump builds the pressure.
- Gauge: reads the pressure, here on the pump.
- Hose: with the oil still, the gauge reads the same pressure as the cylinder.
- Cylinder: its piston area (A) turns pressure into force.
- Piston: the force F = p × A.
For example, Staht's 18 t cylinder has a 25.1 cm² piston: at 700 bar (10,153 psi) it gives 700 × 25.1 ÷ 100 = 176 kN.

Range: above the highest pressure
10,000 psi and 700 bar are used as the same rating (700 bar is 10,153 psi). For a system that can reach 700 bar, a 700 bar gauge works at the very top of its scale, where the element is most strained and a dial gauge wears fastest; a 1000 bar (14,504 psi) gauge puts 700 bar at 70% of its scale, inside the 25% to 75% band makers advise. Never connect a gauge to a system that can exceed the gauge's maximum. See how to choose a pressure gauge.
Accuracy at the pressure you test at
Most hydraulic gauges state accuracy as a percentage of full scale, so the error in bar is the same at every reading and largest as a share of a low reading. A 1000 bar gauge at 0.25% is within ±2.5 bar (±36 psi): 0.36% of a 700 bar reading, but 1.25% of a 200 bar (2,901 psi) one. On a cylinder the error carries into the force: ±2.5 bar on a 25.1 cm² piston is ±0.63 kN. See pressure gauge accuracy.
Keeping the peak
In a load or proof test the pressure that matters is the highest one reached, and it may only last a moment. A dial gauge can have a maximum (drag) pointer that stays at the highest reading; a digital gauge holds the peak on its screen. The G1 Pro holds the peak on its screen with a short press of its yellow button, and works without the app. See how to read a pressure gauge.
From pressure to force
A gauge reads pressure, not force. Force = pressure × the effective area the oil pushes on: kN = bar × cm² ÷ 100. Some dial gauges add a force scale in tonnes or kN; it is right only for a cylinder of the area it was made for, and only one at a time. Specialist tools such as bolt tensioners publish their own pressure-to-load figures: use the maker's. This is the general rule for hydraulic cylinders, not a list of what the G1 Pro connects to. Work it through with the pressure to force calculator.
Connecting the gauge
Hydraulic gauges screw into a gauge port on the pump or a manifold, or connect through a quick connect coupler. Threads differ: G1/4 (BSPP) is parallel and seals on a washer, 1/4" and 1/2" NPT are tapered and seal on the thread, and they don't screw together. See pressure gauge threads.
The G1 Pro has a G1/4 parallel thread, sealed with a G1/4 seal washer. Staht's G1/4 quick connect fittings, sold separately, are the female 802-020 (£160.00 ex VAT) and the male 802-021 (£85.00 ex VAT), each rated to 1000 bar. Not sure it fits? Send a photo of your pump's coupler or gauge port to sales@staht.com or call +44 (0)121 817 0620, and we'll tell you whether it can be connected, and with what.
Pulsation and vibration
A dial gauge on a powered pump can flutter with each stroke. A liquid fill steadies the pointer, and a snubber slows the pressure reaching the gauge. See liquid-filled pressure gauges and pressure gauge snubbers.
Safety at 700 bar and above
Oil escaping at these pressures can be injected under the skin, an injury that may need amputation or major surgery. Never feel for leaks with your hands, release the pressure before connecting or disconnecting anything, and replace damaged hoses. Never exceed the gauge's or any component's maximum working pressure. See pressure gauge safety.
The Staht G1 Pro
The Staht G1 Pro is a calibrated digital Bluetooth pressure gauge for hydraulic pumps and cylinders, reading up to 1000 bar (14,504 psi), accurate to 0.25% of full scale (±2.5 bar, ±36 psi) and UKAS traceable. Its colour screen shows the pressure in bar, live and peak, and the free Staht Connect app shows the force in kN or lbf from the cylinder's piston area. £585.00 ex VAT (£702.00 inc VAT). See all our digital pressure gauges.
It is the gauge in every Staht heavy duty test kit, with a two-stage pump, a 3 m hose and a hollow bore cylinder, for load and proof tests on large fixings, anchors and rebar. Staht calibrates pressure gauges up to 1000 bar, its own and other makes: see pressure gauge calibration.
Questions
A gauge that reads the oil pressure in a hydraulic system, such as a pump, hose or cylinder, usually in bar and psi, and often to 700 bar (10,000 psi) or more.
One with a maximum above the highest pressure the system can reach, so 700 bar sits well inside its scale. A 1000 bar (14,504 psi) gauge puts 700 bar at 70% of full scale.
Only as a second scale made for one cylinder's area. Otherwise multiply the pressure by the piston area: kN = bar × cm² ÷ 100. The G1 Pro's free app does this for any cylinder whose area you enter.
Through a gauge port or coupler that matches the gauge's thread, usually on the pump or a manifold, with the pressure released first. For the G1 Pro, send us a photo of the port and we'll tell you whether it can be connected, and with what.
While oil flows, the hose and fittings cause a pressure drop. With the oil still, as when a load is held, the pressure is the same throughout.
Nearly: 700 bar is 10,153 psi and 10,000 psi is 689.5 bar. Tools use the two as the same rating.
Sources
- Staht G1 Pro gauge user manual, Revision 1, 04/02/2026, Staht
- Staht Heavy Duty Test Kit brochure (the G1 Pro's range and accuracy), Staht
- 18 t cylinder with base, G1/4 quick connect: data sheet (TDS 186), Staht
- Staht G1 Pro product page, Staht
- G7 hydraulic pressure gauge, 4" face, 10,000 psi (700 bar) maximum, Enerpac
- How to select a pressure gauge range, Ashcroft
- High pressure fluid injection hazards, HSE
- NIST Guide to the SI, Appendix B.8: factors for units listed alphabetically, NIST
A digital hydraulic gauge to 1000 bar
Accurate to 0.25% of full scale, with peak hold and a free app that records each test. £585.00 ex VAT.