How to read a pressure gauge

In short
To read a dial pressure gauge: find the unit printed on the dial (bar, psi or both), work out what one small division is worth (the difference between two numbered marks divided by the divisions between them), then count from the last number below the pointer. Read with your eye straight in front of the pointer, and check the gauge reads zero with no pressure. On a dual-scale gauge, read the scale in the unit you need; a digital gauge shows the number directly.
Reading a dual-scale dial
- bar scale: the outer numbers, 0 to 700 bar, numbered every 100 bar.
- psi scale: the inner red numbers, 0 to 10,000 psi.
- Pointer: here at 350 bar, which the inner scale shows as just over 5,000 psi (5,076 psi).
- Maximum pointer: the red pointer left at the highest pressure reached, here 520 bar (7,542 psi).
- Small divisions: 10 bar each on this dial (100 bar ÷ 10 divisions).

Step by step
- Check the unit. It is printed on the dial: bar, psi, kPa, MPa or kg/cm². Many gauges carry two scales.
- Find the value of one division. Take two numbered marks, subtract, and divide by the number of spaces between them: 100 bar with 10 spaces is 10 bar a division.
- Read the pointer. Start from the numbered mark below it and add the divisions. Between two marks, estimate the fraction of a division.
- Look straight on. Viewed from the side, the pointer seems to sit against a different mark (parallax). Some test gauges have a mirror band: line the pointer up with its reflection.
- Check zero. With no pressure, the pointer should rest on zero. If it doesn't, the reading is out by that much or more: see pressure gauge problems.
Reading in bar, psi, kg/cm² and MPa
1 bar = 14.504 psi = 1.0197 kg/cm² = 0.1 MPa. A gauge reading 7 bar is reading about 101.5 psi. A dial in MPa has small numbers: 70 MPa is 700 bar. To change units, use the pressure converter.
Most gauges read gauge pressure, the pressure above the atmosphere; a few read absolute pressure. See gauge vs absolute pressure.
The maximum pointer and peak readings
Some dial gauges have a second, often red, pointer that the main pointer pushes up and leaves behind at the highest pressure reached (a maximum or drag pointer). Read it after the test, then reset it. A digital gauge with peak hold does the same on its screen.
Reading a hydraulic pressure gauge
A hydraulic gauge on a pump or cylinder reads the pressure in bar or psi, not the force. Some dials add a force scale (tonnes or kN) for one particular cylinder; it is right only for a cylinder of that area. To turn pressure into force for any cylinder, multiply by the piston area: kN = bar × cm² ÷ 100. See the pressure to force calculator and hydraulic pressure gauges.
How exact is the reading?
No finer than the gauge's accuracy: a 700 bar gauge at 1% of full scale is within ±7 bar (±102 psi) at any reading, however carefully it is read. See pressure gauge accuracy.
A gauge with the number on screen
The Staht G1 Pro is a calibrated digital Bluetooth pressure gauge for hydraulic pumps and cylinders, reading up to 1000 bar (14,504 psi), accurate to 0.25% of full scale (±2.5 bar, ±36 psi) and UKAS traceable. Its colour screen shows the pressure in bar, live and peak, and the free Staht Connect app shows the force in kN or lbf from the cylinder's piston area. £585.00 ex VAT (£702.00 inc VAT). See all our digital pressure gauges.
Questions
Find the unit on the dial, work out what one small division is worth, then count divisions from the numbered mark below the pointer. Read straight on, and check the gauge reads zero with no pressure.
Read the bar scale (often the outer one). 1 bar is 14.5 psi. If the dial is numbered every 100 bar with 10 divisions between, each division is 10 bar.
Use the scale in the unit you want: the two scales show the same pressure. The pointer at 350 bar sits at about 5,076 psi on the psi scale.
A reading other than zero with no pressure applied. Every reading is then out by at least that much. Have the gauge checked or calibrated.
Usually a maximum (drag) pointer, which stays at the highest pressure reached until reset. On some gauges a red mark or band shows a set or maximum pressure.
Read the pressure in bar or psi as on any gauge. For the force, multiply by the cylinder's piston area: kN = bar × cm² ÷ 100.
Sources
A digital hydraulic gauge to 1000 bar
Accurate to 0.25% of full scale, with peak hold and a free app that records each test. £585.00 ex VAT.