Guide

Pressure gauge problems

In short

A gauge that doesn't return to zero has usually been overpressured or worked too near the top of its range, so its element has taken a permanent set, or its pointer has come loose. A fluttering pointer means pulsation or vibration. A bent or broken pointer points to a pressure spike. In each case the readings can't be trusted: recalibrate or replace the gauge, and fix the cause, usually with a higher range, a liquid fill or a snubber.

Symptoms, causes and fixes

What you seeLikely causeWhat to do
Doesn't return to zero with no pressureOverpressure or long use near the top of the range (the element has taken a set); a loose pointer; a gauge needing ventingVent and check; recalibrate or replace; choose a higher range
Pointer pressed against the stop pinPressure at or above full scale: the range is too lowRelease pressure; replace with a higher range
Pointer fluttersPulsation from pumps or fast valvesLiquid-filled gauge, snubber, or move the gauge
Pointer bent, broken or nickedA pressure spike slammed it into the stopReplace; fit a snubber; check the range
Pointer, window or back plate missing; dust on the dialMechanical vibrationLiquid fill; mount firmly away from vibration
Discoloured dial or fillToo much heatMove it away from heat; a gauge rated for the temperature
Sticks, or moves in jumpsWorn or dirty movement; clogged port or snubberClean the port or snubber; recalibrate or replace
Reads wrong but returns to zeroDrift since its last calibrationCalibrate it

Not returning to zero

First release all the pressure and check the gauge really is at zero pressure. On a liquid-filled gauge, venting the case can bring the pointer back. Watch for the stop pin: on many dials the pointer rests against a pin at zero, which can hide a gauge that would read below zero; a zero box printed round the zero mark shows how far off a healthy gauge may sit.

If it still sits off zero, the element has probably been stretched by overpressure or by long work near the top of the range. Some gauges have a zero adjustment, but resetting the pointer doesn't put back an element that has taken a set: the gauge needs calibrating or replacing.

Fluttering and vibration

Fast cycling of pressure wears the movement and can end in a Bourdon tube rupture; vibration can shake the pointer, window or back plate loose. A liquid fill damps both; a snubber slows pulsation before it reaches the gauge. Moving the gauge away from the pulsation or vibration helps most.

Do pressure gauges go bad?

Yes. Every gauge drifts with use, and overpressure, spikes, vibration, pulsation, heat and corrosion all shorten its life. Calibrate gauges at a set interval and after any drop, overload or doubtful reading: see how often to calibrate a pressure gauge. For the readings you report, a gauge you can't trust is worse than none.

Digital gauges

A digital gauge has no pointer to stick or flutter, but its sensor can drift or be damaged by overpressure in the same way, and a low battery can stop it. Check its zero with no pressure applied, keep it within its range and calibrate it on the same schedule.

Calibration at Staht

Staht calibrates pressure gauges up to 1000 bar, its own and other makes, with a UKAS traceable certificate: see pressure gauge calibration. The Staht G1 Pro is a calibrated digital Bluetooth pressure gauge for hydraulic pumps and cylinders, reading up to 1000 bar (14,504 psi), accurate to 0.25% of full scale (±2.5 bar, ±36 psi) and UKAS traceable. Its colour screen shows the pressure in bar, live and peak, and the free Staht Connect app shows the force in kN or lbf from the cylinder's piston area. £585.00 ex VAT (£702.00 inc VAT). See all our digital pressure gauges.

Questions

Sources

  1. The top five pressure gauge failure causes, Swagelok
  2. What is a zero box vs a dial pin on a pressure gauge, and why it matters, Ashcroft
  3. Why should my pressure gauge pointer be in the center of the scale?, Ashcroft
  4. Pressure gauge maintenance and troubleshooting, Tameson
  5. Liquid filled pressure gauge, Tameson
  6. Pressure gauge calibration, Staht

A digital hydraulic gauge to 1000 bar