In short
A gauge that doesn't return to zero has usually been overpressured or worked too near the top of its range, so its element has taken a permanent set, or its pointer has come loose. A fluttering pointer means pulsation or vibration. A bent or broken pointer points to a pressure spike. In each case the readings can't be trusted: recalibrate or replace the gauge, and fix the cause, usually with a higher range, a liquid fill or a snubber.
Symptoms, causes and fixes
| What you see | Likely cause | What to do |
|---|---|---|
| Doesn't return to zero with no pressure | Overpressure or long use near the top of the range (the element has taken a set); a loose pointer; a gauge needing venting | Vent and check; recalibrate or replace; choose a higher range |
| Pointer pressed against the stop pin | Pressure at or above full scale: the range is too low | Release pressure; replace with a higher range |
| Pointer flutters | Pulsation from pumps or fast valves | Liquid-filled gauge, snubber, or move the gauge |
| Pointer bent, broken or nicked | A pressure spike slammed it into the stop | Replace; fit a snubber; check the range |
| Pointer, window or back plate missing; dust on the dial | Mechanical vibration | Liquid fill; mount firmly away from vibration |
| Discoloured dial or fill | Too much heat | Move it away from heat; a gauge rated for the temperature |
| Sticks, or moves in jumps | Worn or dirty movement; clogged port or snubber | Clean the port or snubber; recalibrate or replace |
| Reads wrong but returns to zero | Drift since its last calibration | Calibrate it |
Not returning to zero
First release all the pressure and check the gauge really is at zero pressure. On a liquid-filled gauge, venting the case can bring the pointer back. Watch for the stop pin: on many dials the pointer rests against a pin at zero, which can hide a gauge that would read below zero; a zero box printed round the zero mark shows how far off a healthy gauge may sit.
If it still sits off zero, the element has probably been stretched by overpressure or by long work near the top of the range. Some gauges have a zero adjustment, but resetting the pointer doesn't put back an element that has taken a set: the gauge needs calibrating or replacing.
Fluttering and vibration
Fast cycling of pressure wears the movement and can end in a Bourdon tube rupture; vibration can shake the pointer, window or back plate loose. A liquid fill damps both; a snubber slows pulsation before it reaches the gauge. Moving the gauge away from the pulsation or vibration helps most.
Do pressure gauges go bad?
Yes. Every gauge drifts with use, and overpressure, spikes, vibration, pulsation, heat and corrosion all shorten its life. Calibrate gauges at a set interval and after any drop, overload or doubtful reading: see how often to calibrate a pressure gauge. For the readings you report, a gauge you can't trust is worse than none.
Digital gauges
A digital gauge has no pointer to stick or flutter, but its sensor can drift or be damaged by overpressure in the same way, and a low battery can stop it. Check its zero with no pressure applied, keep it within its range and calibrate it on the same schedule.
Calibration at Staht
Staht calibrates pressure gauges up to 1000 bar, its own and other makes, with a UKAS traceable certificate: see pressure gauge calibration. The Staht G1 Pro is a calibrated digital Bluetooth pressure gauge for hydraulic pumps and cylinders, reading up to 1000 bar (14,504 psi), accurate to 0.25% of full scale (±2.5 bar, ±36 psi) and UKAS traceable. Its colour screen shows the pressure in bar, live and peak, and the free Staht Connect app shows the force in kN or lbf from the cylinder's piston area. £585.00 ex VAT (£702.00 inc VAT). See all our digital pressure gauges.
Questions
Usually overpressure, or long use near the top of the range, has stretched the element so it no longer springs back; or the pointer has come loose. Release all pressure, vent a liquid-filled gauge, then recalibrate or replace it.
Release all pressure first. Some gauges have a zero adjustment; on others the pointer can be reset by a calibration lab. If the element has been overpressured, re-zeroing won't make it accurate: calibrate or replace it.
Pulsation from a pump or fast valves, or vibration. A liquid-filled gauge or a snubber steadies it.
Yes: they drift with use and are damaged by overpressure, spikes, vibration, pulsation, heat and corrosion. Calibrate them at a set interval.
The most common causes are overpressure, pressure spikes, mechanical vibration, pulsation and too much heat.
The pressure is at or above the gauge's full scale: the range is too low for the system, and the gauge can be damaged.
Sources
- The top five pressure gauge failure causes, Swagelok
- What is a zero box vs a dial pin on a pressure gauge, and why it matters, Ashcroft
- Why should my pressure gauge pointer be in the center of the scale?, Ashcroft
- Pressure gauge maintenance and troubleshooting, Tameson
- Liquid filled pressure gauge, Tameson
- Pressure gauge calibration, Staht
A digital hydraulic gauge to 1000 bar
Accurate to 0.25% of full scale, with peak hold and a free app that records each test. £585.00 ex VAT.