In short
Never let a gauge see more than its maximum pressure, and choose its range so the working pressure sits mid-scale. Where a burst could hurt someone, use a safety pattern gauge: a solid wall between the measuring element and the dial, and a blow-out back that releases a burst to the rear, away from the person reading it. Fit an isolation valve, release pressure before disconnecting, and treat leaking hydraulic oil as dangerous: it can be injected under the skin.
Overpressure
A gauge's element is a spring. Taken past its limit it stretches permanently, the pointer no longer returns to zero, and in the worst case the Bourdon tube ruptures. A pointer pressed against its stop pin means the gauge's range is too low for the system. Makers say a gauge may survive 130% to 150% of its range, depending on the range, but no reading above full scale can be trusted. Use a range about twice the working pressure, and a snubber where spikes are likely. See how to choose a pressure gauge.
A safety pattern gauge in section
- Window: at the front, made so it won't shatter into splinters.
- Solid wall: a wall a burst can't break through, between the measuring element and the dial and window.
- Blow-out back: opens to release pressure, medium and parts to the rear.
- Socket: the connection.
The person reading the gauge stands at the front, protected by the solid wall; the space behind the gauge must stay clear.

Safety versions in EN 837-1, as gauge makers describe them
| Version | What it has | Protection |
|---|---|---|
| S1 | A vent or blow-out plug in the back of the case | A burst can escape backwards, but nothing solid shields the front |
| S2 | A blow-out back | More of the back gives way, but still no solid wall at the front |
| S3 | A solid wall between the measuring element and the dial, a blow-out back and a window that won't splinter | The most: the front is shielded and a burst goes out of the back |
When to use a safety pattern (S3) gauge
One maker, WIKA, points with reference to EN 837-2 (selection and installation) to S3 for gases and vapours from about 25 bar (363 psi), and below that for flammable or toxic gases, hydrogen, strongly pulsating gas lines and gauges where people work. A gas stores far more energy than a liquid at the same pressure, so a burst is more violent.
Two cautions: keep the space behind a blow-out back clear (not against a wall, a pipe or a cable tray, and never where people stand), and remember that S3 protects the person, not the gauge: it does not replace overpressure protection.
Hydraulic pressure: injection injuries
Oil released from a hydraulic system can be injected under the skin, an injury that may need amputation or major surgery, and even pinprick punctures in pipework can cause one. The HSE lists searching for leaks with bare hands, makeshift couplings, damaged hoses and not releasing pressure before work as common causes. Anyone injected needs professional medical treatment at once: prompt action can save the limb.
- Release the pressure before connecting or disconnecting a gauge or hose.
- Never feel for a leak with your hands.
- Use couplings and fittings rated for the pressure, and replace damaged hoses.
- Never exceed the lowest maximum working pressure of any part: gauge, hose, fitting or cylinder.
Fitting and removing gauges safely
Fit an isolation valve so a gauge can be shut off and removed; release the pressure trapped behind it before unscrewing the gauge. Tighten with a spanner on the socket's flats, never by turning the case by hand. Mount gauges where they can be read without standing in front of a blow-out path, and away from heat. See pressure gauge threads.
Using the G1 Pro safely
The G1 Pro is to be used by a competent person, never above its 1000 bar maximum working pressure, and after reading its manual. It is for use from -10 °C to +50 °C, and not under water or in heavy rain. The Staht G1 Pro is a calibrated digital Bluetooth pressure gauge for hydraulic pumps and cylinders, reading up to 1000 bar (14,504 psi), accurate to 0.25% of full scale (±2.5 bar, ±36 psi) and UKAS traceable. Its colour screen shows the pressure in bar, live and peak, and the free Staht Connect app shows the force in kN or lbf from the cylinder's piston area. £585.00 ex VAT (£702.00 inc VAT). See all our digital pressure gauges.
Questions
A gauge built to protect the person reading it if the element bursts: a solid wall between the element and the dial, a blow-out back that sends the burst out of the rear, and a window that won't splinter. EN 837-1 calls the full version S3.
It gives way under a burst so pressure, medium and loose parts escape out of the back of the case instead of through the window. Keep the space behind it clear.
As gauge makers describe them: S1 has a vent or blow-out plug in the back; S2 a blow-out back; S3 adds a solid wall between the element and the dial, and a window that won't splinter, so the front is shielded.
The element can stretch permanently, so the gauge reads wrongly and no longer returns to zero, or in the worst case the tube ruptures. Replace or recalibrate a gauge that has been overpressured.
Yes. A leak can inject oil under the skin, which may need amputation or major surgery. Never feel for leaks by hand, and release pressure before disconnecting.
Sources
- S3 safety pressure gauges: selecting the correct solid front and blow-out direction, ICS Schneider Messtechnik
- How to select a pressure gauge range, Ashcroft
- The top five pressure gauge failure causes, Swagelok
- High pressure fluid injection hazards, HSE
- Hydraulic injection injury (safety bulletin), HSE
- Pressure gauge maintenance and troubleshooting, Tameson
- Staht G1 Pro gauge user manual, Revision 1, 04/02/2026, Staht
A digital hydraulic gauge to 1000 bar
Accurate to 0.25% of full scale, with peak hold and a free app that records each test. £585.00 ex VAT.