In short
Both measure the pull in a line between two points. The Staht in-line kit holds the t25 load cell you use for pull tests in the line, measures up to 25 kN and records each test in the free Staht Connect app; it costs £425 ex VAT without the load cell. A dynamometer is a separate calibrated link. The Tractel, Crosby Straightpoint and Dillon models compared here are stated to 0.1% of full scale, against ±1.5% for the t25, and their makers' ranges go to 250 or 300 tonnes. Use the kit between anchorage points up to 25 kN; use a dynamometer for higher loads, crane and rigging work, closer accuracy, or monitoring a load over time.
At a glance
| Staht in-line kit range | 0 to 25 kN (5,620 lbf), with a Staht t25 load cell |
|---|---|
| Staht t25 load cell accuracy | ±1.5% of full scale: ±0.375 kN at any reading |
| Dynamometers compared here, accuracy | 0.1% of full scale: Tractel Dynafor Expert, Crosby Straightpoint Radiolink plus, Dillon EDXtreme up to 50 t |
| Largest in each maker's line-up | Tractel Dynafor Pro 250 t (Dynafor Expert to 10 t); Crosby Straightpoint Radiolink plus 300 t; Dillon EDXtreme 250,000 kgf |
| Staht in-line kit price | £425 ex VAT; with a t25 load cell bought on its own (£1,225 ex VAT), £1,650 ex VAT |
| Staht Connect app and reports | Free, with no subscription, including team use |
How they differ
- What each is. The in-line kit is a set of steel test plates, a 4 tonne M16 eyebolt, a 3.2 tonne shackle and a 40 kN karabiner that hold a Staht t25 load cell in the line. The load cell isn't in the kit: you use the one from your t25 pull tester, lifted out of its bridge, or buy one. A dynamometer (sold as a load link, load cell or crane scale) is one calibrated link, rigged into the line with shackles.
- Capacity. The kit measures up to 25 kN. The smallest models that reach 25 kN are the Tractel Dynafor Expert 3.2 t (about 31.4 kN), the Crosby Straightpoint Radiolink plus 6.5 t (about 63.8 kN) and the Dillon EDXtreme EDx-5T (50,000 N); the 2.5 t Radiolink plus (about 24.5 kN) and the 20,000 N EDx-2T stop just under 25 kN. Their ranges go much higher: Tractel's Dynafor Pro to 250 t, the Radiolink plus to 300 t and the EDXtreme to 250,000 kgf.
- Accuracy. Staht states ±1.5% of full scale for the t25 load cell: ±0.375 kN at any reading. Tractel, Crosby Straightpoint and Dillon state 0.1% of full scale for these models: about ±0.03 kN on the Dynafor Expert 3.2 t, ±0.06 kN on the Radiolink plus 6.5 t and ±0.05 kN on the EDx-5T.
- Read-out. The t25 shows live and peak load together on its own colour screen. The Dynafor Expert is read on Tractel's HHD handheld, a large display or a phone. The Radiolink plus is read on Crosby Straightpoint's handheld or a phone. The EDXtreme has its own screen and an optional radio remote.
- Records. The t25 sends each test to the free Staht Connect app over Bluetooth, with photos and a map pin, for reports at app.staht.com. Tractel and Crosby Straightpoint have free phone apps, with PC logging software on top (Tractel's Dynasoft is licensed by the year); the EDXtreme keeps up to 255 logs on board. They're made for monitoring loads.
- Applying the load. Neither applies the load. Staht's manual has you connect the kit's shackle to a ratchet lever hoist, or similar, rated at least to the test load. A dynamometer measures what the hoist, crane or winch it's rigged to applies.
Where do these figures come from?
Staht's figures come from its data sheets, brochures, manuals and product pages, read on 15 November 2026. Tractel's come from its UK Measure and Control catalogue 2024 and its Dynafor Expert technical sheet; Crosby Straightpoint's from its Load Monitoring catalogue; Dillon's from its EDXtreme product page and specification sheet, all read on 15 November 2026. Each is listed under Sources.
Makers give dynamometer capacities in tonnes. We've converted them at 9.81 kN a tonne and rounded. We haven't tested the Tractel, Crosby Straightpoint or Dillon equipment, and this page doesn't rate anyone's products. Each value is in the maker's own terms, prices aren't compared, and specifications change: check each maker's current information before you buy.
25 kN tests: the Staht in-line kit beside three dynamometers
| Staht In-Line Test Kit with a t25 load cell | Tractel Dynafor Expert 3.2 tSource, read 15 November 2026 | Crosby Straightpoint Radiolink plus RLP6T5Source, read 15 November 2026 | Dillon EDXtreme EDx-5TSource, read 15 November 2026 | |
|---|---|---|---|---|
| Maximum load | 25 kN (5,620 lbf) | 3.2 t (about 31.4 kN) | 6.5 t, 14,300 lb (about 63.8 kN) | 50,000 N (5,000 kgf, 10,000 lbf) |
| Largest in the maker's range | 25 kN: one kit | 250 t (Dynafor Pro); the Dynafor Expert range is 0.5 to 10 t | 300 t (RLP300T) | 250,000 kgf (EDx-250T) |
| Accuracy, as the maker states it | ±1.5% of full scale (±0.375 kN), the t25 load cell | 0.1% of full scale at 21 °C, 0.2% with the IP67 option: ±3.2 kg | ±0.1% of full scale | 0.1% of capacity up to the EDx-50T, in normal resolution with Dillon's shackles |
| Resolution | Not published | 0.5 kg | 0.001 t (2 lb) | 50 N, or 10 N in enhanced mode |
| Read-out | Colour screen on the load cell showing live and peak load together | On a wireless display: the Dynafor HHD handheld up to 400 m, a large AL63 display (200 m in Tractel's UK catalogue), or the free Dynafor app over Bluetooth up to 30 m | Long-range version: SW-HHP handheld up to 1,000 m. Bluetooth version: free HHP app up to 100 m | Built-in LCD with 26 mm digits; optional radio remote, open-air range up to 200 ft |
| Peak hold | Yes | Yes: 4 readings a second, up to 32 in peak hold | Yes: 3 readings a second as standard, up to 200 to order | Yes: peak capture at 10, 100 or 1,000 Hz |
| Records and reports | Staht Connect, free with no subscription: peak load, target load, pass or fail, time, photos and a map pin; reports at app.staht.com | Free Dynafor app; Dynasoft software, licensed by the year, for data saved in the HHD | Free HHP app; INSIGHT software logs up to 126 load cells | Up to 255 logs on board, with date and time; export over RS-232 or USB |
| Calibration | Calibrated for a year from purchase, with a certificate; annual recalibration recommended (Staht: £135 ex VAT, 12-month certificate) | Calibration report supplied; ISO 376 calibration an option | Certificates of calibration and proof test supplied | Certificate traceable to NIST, with a curve of readings; recalibrate every 12 months |
| Overload, as the maker states it | Overload warning at 30 kN; no safety factor published | Test load 4.8 t; safety factor at least 4 | Safety factor 7:1 | Safe overload 200%; ultimate 700%; proof load 150% |
| Weight, as the maker states it | Kit 2.8 kg, plus the t25 load cell 1.39 kg | 2.3 kg | 2.4 kg | 2.5 kg; 6 kg with shackles |
| Protection and temperature | Use from −10 to +50 °C; not underwater or in heavy rain | IP64 (IP67 an option); −20 to +50 °C | IP67 / NEMA6; −10 to +50 °C | IP68 / NEMA4X; −20 to +70 °C |
| In the box | Test plates, 40 kN karabiner, 3.2 t shackle and pin, 4 t M16 eyebolt, padded bag. The t25 load cell isn't included | Dynamometer, user manual, calibration report and declaration of conformity, in a plastic case | Load cell in a rugged case, with manuals, calibration and proof test certificates and CE conformity | Dynamometer, calibration certificate, manual and batteries, in a plastic carry case; shackles an option |
Each range's smallest model that reaches 25 kN. Each maker's published figures, read on 15 November 2026. Tractel's are from its UK catalogue and Dynafor Expert technical sheet, Dillon's from its product page and the specification sheet it links to. Tonnes converted at 9.81 kN.
When is the in-line kit the right tool?
- You already have a t25. The kit adds in-line testing to the load cell you use for anchor and eyebolt pull tests, for £425 ex VAT. Staht's brochure puts it this way: you use the load cell and the Staht Connect app "without the need to carry and calibrate a separate measuring device".
- The force is up to 25 kN, between two anchorage points. Staht names the uses as testing between fall protection anchor posts, overhead lifting points and rail systems. Its brochure says the kit can be used to test and verify fall protection engineered systems products to OSHA regulations and BS 7883:2019 Annex D and E.
- You want the test on record with your other tests. Each in-line test goes into Staht Connect like a pull test: peak load, target load, pass or fail, the time, photos and a map pin, with reports at app.staht.com, free and with no subscription.
- You want the fittings in one bag. The kit comes with the karabiner, eyebolt and shackle to connect it.
Check the accuracy against your test force first. At ±0.375 kN, the t25 is within 5% of the reading from 7.5 kN and within 10% from 3.75 kN. See gauge accuracy.
When is a dynamometer the better tool?
- Above 25 kN. The in-line kit stops at 25 kN. Dynamometers come in ranges to 250 t (Tractel Dynafor Pro, Dillon EDXtreme) and 300 t (Crosby Straightpoint Radiolink plus).
- Crane, lifting and rigging work. Tractel lists overhead weighing, towing and load monitoring on lifting equipment among the Dynafor Expert's uses; Crosby Straightpoint names crane and rigging, offshore wind and shipping among its markets; Dillon says the EDXtreme can work as a digital hanging scale, and its remote can total the load across several links in a lift.
- Closer accuracy. At 0.1% of full scale, a 3.2 t Dynafor Expert's stated error is ±3.2 kg (about ±0.03 kN), against the t25's ±0.375 kN.
- Reading from a distance. The long-range Radiolink plus reaches 1,000 m to its handheld and the Dynafor Expert 400 m to Tractel's HHD; the Dillon remote, 200 ft in open air.
- Monitoring over time, or at several points. Crosby Straightpoint's INSIGHT software logs up to 126 load cells at once, and it offers an overload alarm and a base station with 4-20 mA, relay or RS485 outputs. Tractel offers Dynasoft Monitoring with the HHD and the Dynafor DMU for thresholds; Dillon an optional audible overload alarm.
- Hazardous areas and harsh weather. The Radiolink plus comes in an ATEX and IECEx version for zones 0, 1 and 2. The Radiolink plus is IP67 and the EDXtreme IP68; Staht's manual says not to use the in-line kit underwater or in heavy rain.
How should the figures be read?
- Accuracy. All four makers state accuracy as a share of full scale, so the possible error in kN is the same at every reading, and a bigger share of a low one. At 10 kN, the t25's ±0.375 kN is 3.75% of the reading; a 3.2 t Dynafor Expert's ±3.2 kg is about 0.3%. Check each calibration certificate for the measured errors.
- Low loads on large links. Tractel gives the Dynafor Expert's minimum load as 10% of its working load limit: 0.32 t on the 3.2 t model. A big dynamometer is the wrong tool for a small force.
- Tonnes and kilonewtons. Dynamometers are sold by the tonne and read in units chosen on the device, such as kg, t, kN or lbf; the t25 reads kN or lbf. One tonne is about 9.81 kN.
- Weight. The t25 load cell (1.39 kg) and the in-line kit (2.8 kg) come to about 4.2 kg; the three dynamometers compared weigh 2.3 to 2.5 kg as their makers state it (Dillon's EDx-5T: 6 kg with its shackles). The in-line kit's weight includes its eyebolt, shackle and karabiner.
Testing a single anchor, eyebolt or davit socket?
In-line testing measures the force between two points. To proof test one anchor, eyebolt or davit socket, use a t25 or t60 pull tester: with the clevis for eyebolts, or with Staht's davit testing adaptor kit for davits. See:
More questions
On the makers' stated figures, yes. The Tractel Dynafor Expert, Crosby Straightpoint Radiolink plus and Dillon EDXtreme (up to the EDx-50T) are stated to 0.1% of full scale; the t25 load cell in the in-line kit to ±1.5% of full scale, ±0.375 kN at any reading. The t25 is within 5% of the reading from 7.5 kN and within 10% from 3.75 kN.
No. Staht's manual sets its maximum at 25 kN (5,620 lbf). For more force in a line, use a dynamometer of the right range. To pull test a single anchor above 25 kN, Staht makes the 60 kN t60 and heavy duty kits of 176 kN and 358 kN.
Not if you have a t25 pull tester: lift its load cell out of the bridge (two quick-release knobs) and fit it between the kit's plates. Otherwise buy a t25 load cell on its own, £1,225 ex VAT. Either way only the load cell needs calibrating.
The t25 pairs over Bluetooth with the free Staht Connect app, which records the peak load, target load, pass or fail and the time, with photos and a map pin. Reports come from app.staht.com, free and with no subscription, including team use.
Staht calibrates the t25 load cell for a year from purchase and recommends calibrating it every year; Staht does it for £135 ex VAT with a 12-month certificate. Dillon says to recalibrate the EDXtreme every 12 months. Tractel supplies the Dynafor Expert with a calibration report, with ISO 376 calibration as an option, and Crosby Straightpoint supplies certificates of calibration and proof test.
Tractel and Dynafor are Tractel's brands; Crosby Straightpoint is a brand of CMCO; Dillon is an Avery Weigh-Tronix, LLC brand. Each is a separate company from Staht Limited.
Sources (read on 15 November 2026)
- Staht In-Line Test Kit data sheet, TDS 138, Staht
- Staht In-Line Test Kit brochure, Staht
- Staht In-Line Tester user manual, Staht
- Staht t25 load cell data sheet, TDS 134, Staht
- Staht t25 Digital Pull Tester brochure, Staht
- Staht t25 Digital Pull Tester Load Cell, Staht
- Staht In-Line Test Kit, in Kit Bag, Staht
- Calibration and service of Staht t60 and t25 testers, Staht
- Staht Connect, Staht
- Measure and Control, Tractel UK catalogue 2024, Tractel
- Dynafor Expert technical sheet, T-7052/EN revision 02, 10/2021, Tractel
- Load Monitoring catalogue (Radiolink plus), Crosby Straightpoint
- EDXtreme Red Dynamometer, Dillon
- EDXtreme Dynamometer specifications, 09815-0014, Dillon
- BS 7883:2019 Personal fall protection equipment. Anchor systems. System design, installation and inspection. Code of practice, BSI
Measure in-line force with your t25
The Staht in-line kit, with the free Staht Connect app.