Guide: Australia

Anchor point testing and certification in Australia

Fil-qosor

In Australia, the model Code of Practice on falls says a competent person should test and approve anchorages before use, and that for insert-type anchors (friction, chemical and screw anchors in drilled holes) this should include a pull-out test, because looking at them can't show how well they grip. SafeWork NSW expects chemical and friction anchors to be load tested every year, and Safe Work Australia's rope access guide says rope access anchors should be load tested before first use and at least annually. AS/NZS 1891.4:2025 is the current standard for selection, use and maintenance, inspection included.

Din il-paġna tispjega kif l-ankri, l-eyebolts u l-punti tal-ankraġġ jiġu ttestjati, spezzjonati u rreġistrati b'mod komuni. Ma tieħux post il-liġi, l-istandards li issemmi, l-istruzzjonijiet tal-manifattur, jew id-deċiżjonijiet tal-persuna responsabbli mix-xogħol jew mis-sistema, li tistabbilixxi t-testijiet, it-tagħbijiet u r-reġim tal-ispezzjoni. Test jirreġistra dak li ġara f'dak in-nhar; ma japprovax ankra għall-użu.

Key figures

Before first useTested and approved by a competent person; pull-out testing for insert-type anchors (model Code of Practice)
Every yearLoad testing of chemical and friction anchors (SafeWork NSW); rope access anchors load tested before first use and at least annually (Safe Work Australia)
Proof loads in the old standards, as WHSQ quotes themHalf the design strength: 7.5 kN for fall arrest anchors (AS/NZS 1891.4:2009), 6 kN for rope access anchors (AS/NZS 4488.2:1997)
Current standardsAS/NZS 1891.4:2025 (selection, use and maintenance) and AS 5532:2025 (single-point anchor devices), both published 19 September 2025
Staht t250 to 25 kN, ±0.375 kN

What is it called in Australia?

Building owners and facility managers buy anchor point certification or recertification, usually as part of a height safety inspection of the roof's anchors, static lines and rails. The test itself is a pull-out test, load test or proof load test. Regulators write about anchorages, fall arrest anchors and insert-type anchors (friction, chemical and screw anchors fixed into a drilled hole). The person doing it is a competent person: the codes define that by knowledge and skills gained through training, qualification or experience, not by a licence. In Queensland a QBCC licence can be needed to install anchors, depending on the scale and value of the work.

On construction sites the same test is called site testing or a proof test of post-installed anchors: see anchor proof testing in Australia.

What does the law ask for?

The WHS laws, and Victoria's OHS laws, don't name a test. They ask the business in control to manage the risk of falls, and the codes of practice say how. Safe Work Australia's model Code of Practice, Managing the risk of falls at workplaces, adopted in states such as Western Australia, says:

  • each anchorage point should have the anchor strength AS/NZS 1891.4 sets (the code names the 2009 edition);
  • anchorages should be tested and approved by a competent person before use, and for insert-type anchors that should include pull-out testing, because a visual check can't show the grip in the concrete;
  • each part of a fall arrest system should be inspected by a competent person after it's installed and before it's used, at regular intervals, and straight after it has arrested a fall.

The same code says insert-type anchors (friction, chemical and screw anchors) shouldn't be used as fall arrest anchors where a fall would load them in direct pull-out.

SafeWork NSW notes that neither AS/NZS 1891.4 nor AS/NZS 5532 is made mandatory by the legislation. The falls code still points to AS/NZS 1891.4, and SafeWork NSW notes that a court may have regard to a standard a code refers to when deciding what is reasonably practicable.

Do anchor points need testing every year?

Chemical and friction anchors, yes, in the regulators' guidance:

  • SafeWork NSW (fact sheet last updated August 2019) expects inspection programmes based on AS/NZS 1891.4, including annual load testing of chemical and friction anchors, to continue for every installed anchor.
  • Safe Work Australia's Guide to managing risks of industrial rope access systems (2022) says anchors should be load tested before first use and then at least annually, and that records of the testing and condition of installed rope access anchors must be kept.
  • Workplace Health and Safety Queensland's guide Anchors for building maintenance (2019) says every post-installed anchor should be proof loaded along its axis after installation and before first use, and again at periodic inspections no more than 12 months apart, without damaging it. Anchors without records of their design, installation and inspection aren't to be used.
  • WorkSafe Victoria's compliance code for construction has a permanently fixed anchorage in regular use inspected by a competent person during the construction phase at what it words as "no less than six-month intervals".

What load is an anchor point proof tested to?

Queensland's 2019 guide quotes two standards that have since been replaced. Under the 2009 edition of AS/NZS 1891.4, anchors that hold by friction or adhesive get a proof load of half their design ultimate strength, as a straight pull along the anchor, after installation and at each periodic inspection. The guide works that out as 7.5 kN for fall arrest anchors, and as 6 kN for industrial rope access anchors under the rope access standard of the time, AS/NZS 4488.2:1997.

The 2009 edition has since been replaced by AS/NZS 1891.4:2025, and AS/NZS 4488.2 by AS/NZS ISO 22846.1 and .2:2020. Standards Australia's summary of the new edition says it has clearer periodic inspection frequencies and criteria, and requirements for inspection registers, but doesn't give the figures. Check the current edition, the anchor maker's instructions and the system designer's documents before you set a load. The test mustn't damage the anchor: a higher load isn't a better test.

The Australian standards for anchor points

StandardWhat it coversStatus
AS/NZS 1891.4:2025, Personal equipment for work at height: Selection, use and maintenanceChoosing, using, inspecting and maintaining fall arrest equipment, anchors included; inspection registersCurrent, published 19 September 2025; replaced AS/NZS 1891.4:2009
AS 5532:2025, single-point anchor devicesHow anchor devices are made and tested by their maker: performance, test methods, marking and instructions. The revision supports installation on many more timber and steel purlin roofsCurrent, published 19 September 2025; replaced AS/NZS 5532:2013, now an Australian-only standard
AS 5216:2026, design of post-installed and cast-in fastenings in concreteHow engineers design anchors in concreteCurrent, published 10 April 2026; replaced AS 5216:2021
AS/NZS ISO 22846.1 and .2:2020, industrial rope accessRope access systemsCurrent; replaced AS/NZS 4488.2:1997

Does AS 5532 mean existing anchors must be replaced?

Not because of the standard itself. SafeWork NSW wrote its fall arrest anchors fact sheet (last updated August 2019) because firms were selling anchor inspection and replacement on the claim that AS/NZS 5532:2013 applied to anchors already installed. It says AS/NZS 5532 is a manufacturing standard that doesn't deal with inspection, testing and maintenance, isn't expected to apply to existing installed anchors, and that AS/NZS 1891.4 is the standard for those. Its replacement, AS 5532:2025, is still a manufacturing standard. SafeWork NSW hasn't updated the sheet since, so if a contractor says the 2025 edition makes your anchors non-compliant, ask for it in writing and check with your state regulator. Damaged anchors, or anchors not installed as their maker instructs, should be put right or replaced.

Who certifies anchor points, and who pays?

A competent person, as the codes say; Safe Work Australia's rope access guide gives a qualified engineer as an example for installing, testing and inspecting rope access anchor devices. The business in control of the building arranges it, usually through its facility or building manager and a height safety contractor; Safe Work Australia's rope access guide says records of the testing and condition of installed anchors must be kept. Whoever does it needs a tester that covers the proof load, a current calibration, and a record for each anchor.

Which Staht tester for anchor point testing?

  • Roof anchors, eyebolts and rope access anchors: the t25 reads to 25 kN, well above 6 or 7.5 kN; its ±0.375 kN accuracy is 5% of a 7.5 kN reading and 6.3% of a 6 kN one. The clevis in every kit fits an anchor's eye; the anchor jaw and threaded washers fit studs and bolts (connecting a tester to the anchor).
  • Larger anchors: the t60 reads to 60 kN.
  • Static lines: the LT swage tester tests swaged ends and the in-line kit measures force between anchorage points, both with the t25 load cell, to 25 kN.

The screen shows live and peak load together. The free Staht Connect app records each anchor's test with a photo, a map pin and the time, for the inspection register.

In Australia, Staht kits are sold, serviced and calibrated by Iccons (Dandenong South, Victoria) and Sky5 (Rosebery, NSW): see where to buy.

What should the inspection record show?

For each anchor: its unique number and place on the roof plan, what it is and what it's fixed into, the load applied and how long it was held, what was seen, the result, and photos. For the visit: the date, the competent person, and the tester's make, serial number and calibration date. Our free proof load test record has fields for each anchor's reference, location, load, hold and result, and for the tester and its calibration; keep the photos and roof plan with it. Roof anchor and eyebolt testing walks through a set-up.

More questions

Sources

  1. Managing the risk of falls at workplaces: model Code of Practice, Safe Work Australia
  2. Managing the risk of falls at workplaces: code of practice (WA), WorkSafe WA
  3. Fall arrest anchors, SafeWork NSW
  4. Guide to managing risks of industrial rope access systems, Safe Work Australia
  5. Anchors for building maintenance, Workplace Health and Safety Queensland
  6. Compliance code: Prevention of falls in general construction, WorkSafe Victoria
  7. Spotlight on AS/NZS 1891.4:2025, Standards Australia
  8. Changes to height safety standards support safer workplaces, Standards Australia
  9. AS 5532:2025, Intertek Inform (Standards Australia distributor)
  10. AS 5216:2026, Intertek Inform (Standards Australia distributor)
  11. AS/NZS 4488.2:1997 (superseded by AS/NZS ISO 22846.1 and .2:2020), Intertek Inform (Standards Australia distributor)